One generator. Three measurement routes.
The Houston FCS-27 test used a 1,000 kW CAT 3512 generator at 80% load. The record reports fuel use through three measurement methods.

Compare fuel input with useful work under recorded operating conditions.
How does CM fuel technology work?

How can fuel technology create wider value?

The protocol. The results. The operating context.
Recorded Protocol

The protocol records a three-hour untreated baseline, three hours of conditioning at 1:1000 and a three-hour formal test at 1:2000. The 1,000 kW generator operated at a documented load of 80%.
Three Measurement Routes

The record reports 12% using the Caterpillar fuel sensor, 11% using a diesel gauge stick and 10.25% using a Flexim F601 ultrasonic meter. These results come from three methods within one test. Read each with its measurement method, equipment, load, dose and observation period.